To gravity feed cracks:
Pour neat HT-175 SLV into vee-notched crack. Continue placement until completely filled. Seal underside of slab prior to filling if cracks reflect through.
To pressure-inject cracks:
Use automated injection equipment of manual methods. Set appropriate injection ports based on system used. Seal ports and cracks with HT Structural Gel or HT Structural Gel Fast. When the epoxy adhesive seal has cured, inject HT-175 SLV with steady pressure. Consult Technical Service for additional information.
To seal slabs:
Spread neat HT-175 SLV over slab. Allow penetration. Remove excess to prevent surface film. Seal interior slabs and above grade exterior slabs only.
For use as an epoxy mortar:
Prime prepared surface with neat HT-175 SLV. Place prepared epoxy mortar before primer becomes tack-free. Place the epoxy mortar using trowels. Compact and level with vibrating screed or trowels. Finish with finishing trowel. Exterior application may darken with ultra violet exposure.